Model Selection
Catalog pre-selection tools for KOBA / IZMAC shock absorbers, Ultrafilter housings and Ordel instrumentation.
For force, flow, pipe and motor calculators, go to Calculators.
KOBA Shock Absorber
1 STEP01 — Direction of movement
Select the direction of impact to start model pre-selection.
2 STEP02 — Application type
Choose the application type that best matches your use case.
3 STEP03 — Data input
Adjustable = KMA/KHA/KSA/KHAT · Self-compensating = KMS
EA = Each. If several absorbers share the load, mass/energy is divided per unit.
Informational; standard catalog oil range is -10…80°C.
g=9.8. ET = m·g·(H+S); Me = m·(H+S)/H. Max H ≈ 1.27 m.
Free fall: ET = m·g·(H+S), Me = m·(H+S)/H. Other: E ≈ 0.5·m·v² + F·s (s = stroke mm ÷ 1000 → metres).
Warning: These results are not binding technical approval. Do not use without checking mounting, safety factors and site conditions. We are not liable for the results.
IZMAC Shock Absorber
1 STEP01 — Direction of movement
Select the direction of impact to start model pre-selection.
2 STEP02 — Application type
Choose the application type that best matches your use case.
3 STEP03 — Data input
Adjustable = IAA/IHA/ISA · Self-compensating = IMS
EA = Each. If several absorbers share the load, mass/energy is divided per unit.
Informational; standard catalog oil range is -10…80°C.
g=9.8. ET = m·g·(H+S); Me = m·(H+S)/H. Max H ≈ 1.27 m.
Free fall: ET = m·g·(H+S), Me = m·(H+S)/H. Other: E ≈ 0.5·m·v² + F·s (s = stroke mm ÷ 1000 → metres).
Warning: These results are not binding technical approval. Do not use without checking mounting, safety factors and site conditions. We are not liable for the results.
Ultrafilter Filter
1 STEP01 — Application / ISO target
Choose the closest application; ISO 8573-1 class and filter stages follow from it.
2 STEP02 — Flow & pressure
Select an application type first.
AG (threaded) / SG (flanged) / HD (high pressure >16 bar) are selected from PDF tables. Lower pressure may need a larger housing.
Warning: These results are not binding technical approval. Do not use without checking mounting, safety factors and site conditions. We are not liable for the results.
Filter ΔP / Life
Not an exact lifetime. Use ΔP indicator (~0.5–0.7 bar) for element change.
Warning: These results are not binding technical approval. Do not use without checking mounting, safety factors and site conditions. We are not liable for the results.
KOBA Buffer
1 STEP01 — Application type
Choose the application type that best matches your use case.
2 Data input
Warning: These results are not binding technical approval. Do not use without checking mounting, safety factors and site conditions. We are not liable for the results.
IZMAC Buffer
1 STEP01 — Application type
Choose the application type that best matches your use case.
2 Data input
Warning: These results are not binding technical approval. Do not use without checking mounting, safety factors and site conditions. We are not liable for the results.
Ordel Model Selection
1 Product category
Choose category → subgroup → see matching Ordel and Semm models.
2 Subgroup
Pick a product family from the catalog, or list all.